Home | About us | News | Service | Contact Us | Agents | RHEOTEK USA | Shop RHEOTEK™

Glass capillary Viscometers
Viscosity Reference Standards
Viscometer Baths
Automatic Kinematic Viscometers
JET & DIESEL AUTO KV ANALYZER
Automatic Polymer Viscometer
Automatic Pulp & CELLULOSE Viscometer
ISO 17025 Calibration
Hydrometers
Thermometers
Biodiesel
Diesel Fuel
New & used lubricants
Petroleum Products
Cloud, Pour & Freeze Point
Sulphur Analyzers
Sulphur Standards
Test Methods
Foreign Language Datasheets
Kinematic Viscosity
Shop RHEOTEK™ Instructions


Poulten Selfe & Lee Ltd
Russell House
Burnham Business Park
Burnham on Crouch
Essex CM0 8TE
United Kingdom

Tel: +44 (0)1621 787100
Fax: +44 (0)1621 787175
E-mail: info@rheotek.com
back print page Download PDF  

RHEOTEK AV-2 Automatic Viscometer

  • Temperature range: 40 to 100°C
  • Viscosity range at 40°C: 1 to 1000 cSt.,mm²/s
  • Viscosity range at 100°C: 1-75 cSt.,mm²/s
  • Applications: New & used lubricants, diesels, residual fuel oils & other petroleum liquids
  • Compliant with IP 543

Precision Capillary Viscometer System

Full method compliance combined with the convenience of completely automated measurement.

Suitable for measuring the viscosity of new oils, residual fuels and distillate fuels, as well as used oils in full compliance with IP 543. Instrument performance meets precision criteria of ASTM D445, IP 71 & ISO 3104.

PRINCIPLE OF OPERATION

At the heart of the AV-2 are two traditional capillary tubes, which determine viscosity by measuring flow times. This ensures optimal precision of measurement but without the inconvenience of maintaining a liquid bath. Instead, the AV-2 combines advanced multi-processor systems, accurate thermal control, super sensitive micro-detectors and very efficient in-situ automatic cleaning system. The instrument is specially well suited to measure black oils and residual fuels.

PRECISION

The RHEOTEK AV-2 is fully compliant with standard test method IP 543 - Determination of the dynamic viscosity of distillate & residual fuel oils and calculation of kinematic viscosity - Automatic capillary tube method. This method shows that there is good correlation between viscosities determined by the automatic capillary tube method and IP 71, ISO 3104 & ASTM D 445 manual kinematic viscosity results.

VISCOSITY & DENSITY

The AV-2 measures flow times & determines viscosity in mPa.s. In addition some models determine density to a precision of four decimal places. The two measured values are used to report kinematic viscosity in mm2/s, cSt. The result database records all measurements and calculations in order to provide complete traceability of results.

RESULTS DATABASE

The RHEOTEK AV-2 is equipped with a very powerful database for extensive management of measurement results. A number of different filtering and sorting options are available for automatic generation of reports. The flexible software allows for the PSL installation engineer to configure this function according to the practices in the individual laboratory.

The AV-2 is available in 6 standard models based upon the following applications:

LUBRICANTS

AV-2 Lubricants
Suitable for measuring the kinematic viscosity of new and/or used lubricating oils at 40 and 100
șC. Each sample is measured at 40 and 100șC simultaneously.
Reported results include kinematic viscosity and Viscosity Index.

DISTILLATE AND RESIDUAL FUELS

AV-2 40/50 Fuels
Suitable for measuring the kinematic viscosity of distillate fuels (diesel and gas oil) at 40
șC and residual fuel oil at 50șC. Two samples are measured simultaneously. Distillates are run first on both viscometers with the temperature set to 40șC. The temperature can then be changed to 50șC.

AV-2 Refinery Fuels
Suitable for measuring the kinematic viscosity of distillate fuels (diesel and gas oil) at 40
șC and residual fuel oil at 50șC, 80șC or 100șC. Distillates run on viscometer 1 and residual fuel oils on Viscometer 2. Viscometer 2 can be set to 50șC, 80șC or 100șC depending on what temperature the laboratory requires.

AV-2 RFO
Suitable for measuring the kinematic viscosity of residual fuel oil at 50
șC, 80șC or 100șC. Two samples are measured simultaneously.
Separate auto sampler needles load simultaneously from two sample vials. Viscometer 1 & 2 operate at the same temperature in the range 50șC to 100șC.

USED MOTOR OILS

AV-2 UMO(40)
Suitable for measuring the viscosity of used motor oil at 40
șC. 2 samples are measured simultaneously. The AV-2 is optimized for high sample throughput with a small sample volume (<5ml). Separate auto sampler needs load from two sample vials simultaneously. Viscometer 1 & 2 operate at 40șC.

AV-2 UMO (100)
Suitable for measuring the viscosity of used motor oil at 100
șC. 2 samples measured simultaneously. The AV-2 is optimized for high sample throughput with small sample volume (<5ml). Separate auto sampler needles load from 2 sample vials simultaneously. Viscometer 1 & 2 operate at 100șC.

Click here to request a quotation

meters testing residual fuel oils.


Copyright Poulten Selfe & Lee Ltd ©2004